A brine tank holds salt and water side by side. The water dissolves the salt, and that brine is what recharges the resin during regeneration. A salt bridge is a hard crust of salt that forms across the tank and leaves an empty space underneath. The top can look full while no brine forms, so the softener runs its cycle without the salt it needs. The first sign is often that the water feels harder again, and that change arrives slowly.
Signs to watch for
The salt level stays high across several weeks even though the unit should be using some. When you check the brine well after a regeneration, you see little or no water. Hardness returns gradually, with spots on dishes or soap that stops lathering as well as it used to. A cycle that seems to run normally still leaves the water hard. Any one of these may have another cause, so look for a pattern across two or three checks.
Check the tank carefully
Look through the lid or open the tank as your manual describes. Use a plain wooden or plastic rod, such as a broom handle, to gently tap the salt and feel for a hollow or a hard crust. Do not use metal tools, and do not reach into the tank while a regeneration is running. Note what you find before you change anything, and follow the steps in your manual for your model.
Break it up and keep watching
If you find a bridge, break it up gently with the rod so water can reach the salt. Then check the brine level after the next regeneration to see whether brine is forming. If the bridge returns quickly, the salt type, the storage conditions and the amount of water in the tank may be part of the cause, so check those next. A short note in your log of salt levels will show whether your changes helped.
When to call for service
If the bridge comes back, the brine level stays low, or hardness continues after you have cleared the salt, call the company that installed the unit or a qualified service technician. Ask them to check the brine valve and float as well as the salt. Keep the notes you took, because a clear record of salt levels and symptoms helps a technician find the cause faster.